hi Jean, Am 26.10.2010 21:06, schrieb Jean Delvare: indeed - I remember having read that before, but just forgot ..I think you forgot to check the FAQ and in particular: http://www.lm-sensors.org/wiki/FAQ/Chapter3#Isetnewlimitsanditdidntwork now setting the limits does work for jc42 _min and _max values, however not for _max_hyst (although the setting seems to exist) The latest config file: bus "i2c-0" "SMBus PIIX4 adapter at 0b00" chip "jc42-i2c-0-18" label temp1 "DRAM_0" set temp1_max 60 set temp1_crit 70 set temp1_max_hyst 65 chip "jc42-i2c-0-19" label temp1 "DRAM_1" set temp1_max 60 set temp1_crit 70 set temp1_max_hyst 65 and the latest output karsten:~/temp$ sudo sensors -s Error: File /etc/sensors.d/jc42.conf, line 7: Failed to set value jc42-i2c-0-18: At least one "set" statement failed Error: File /etc/sensors.d/jc42.conf, line 14: Failed to set value jc42-i2c-0-19: At least one "set" statement failed (actually I get the same error message for the K10temp _min & _max settings, but maybe these are hardwired?) Thanks.. I try my best not to look too stupid, as I'm really a Linux beginner..Honestly, you are a very pleasant user to deal with. best regards - Karsten |
_______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors