On 2012-12-10 10:39, Frank Schäfer wrote:
Am 09.12.2012 18:53, schrieb Matthew Gyurgyik:
On 12/09/2012 12:06 PM, Frank Schäfer wrote:
Forget this sh... (never do multiple things at the same time ;) )
Reg 0x50 is set to according to rc_type specified in the selected
remote
control map.
So if the correct map is selected, everything should be fine (as
long as
it is RC_TYPE_NEC or RC_TYPE_RC5 because we don't support others
yet).
RC_MAP_KWORLD_315U and RC_MAP_MSI_DIGIVOX_III are both RC_TYPE_NEC,
so
the stick seems to use no NEC protocol.
Matthew, insert a line
ir_config = 0x01;
before
380 em28xx_write_regs(dev, EM2874_R50_IR_CONFIG, &ir_config,
1);
in em28xx-input.c and see if something shows up in the dmesg
output.
Regards,
Frank
That seems to be a bit more successful!
Here is the dmesg output:
[root@tux ~]# dmesg -t | sort | uniq | grep 'em28xx IR' | grep
handle
em28xx IR (em28xx #0)/ir: 6em28xx_ir_handle_key: toggle: 0, count:
1,
key 0x61d6
em28xx IR (em28xx #0)/ir: 6em28xx_ir_handle_key: toggle: 0, count:
2,
key 0x61d6
em28xx IR (em28xx #0)/ir: 6em28xx_ir_handle_key: toggle: 1, count:
1,
key 0x61d6
em28xx IR (em28xx #0)/ir: em28xx_ir_handle_key: toggle: 0, count:
1,
key 0x61d6
em28xx IR (em28xx #0)/ir: em28xx_ir_handle_key: toggle: 0, count:
2,
key 0x61d6
em28xx IR (em28xx #0)/ir: em28xx_ir_handle_key: toggle: 1, count:
1,
key 0x61d6
em28xx IR (em28xx #0)/ir: em28xx_ir_handle_key: toggle: 1, count:
2,
key 0x61d6
I pressed all the buttons on the remote (40 buttons).
Did you cut the dmesg output ? Or do you really get these messages
for
key 0x61d6 only ?
Correct, I got these messages for key 0x61d6 regardless of the physical
key pressed.
It seems like things are working different with reg 0x50 = 0x01.
Taking
a look into the datasheet might help, but I don't have it. ;)
Regards,
Frank
Thanks,
Matthew
--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majordomo@xxxxxxxxxxxxxxx