On Fri, 31 Jul 2020 13:17:53 +0200 Enric Balletbo i Serra <enric.balletbo@xxxxxxxxxxxxx> wrote: > Hi Gwendal, > > Thank you for your patch. > > On 28/7/20 22:48, Gwendal Grignou wrote: > > BMI160 Minimium gyroscope frequency in normal mode is 25Hz. > > When older EC firmware do not report their sensors frequencies, > > use 25Hz as the minimum for gyroscope to be sure it works on BMI160. > > > > Fixes: ae7b02ad2f32d ("iio: common: cros_ec_sensors: Expose cros_ec_sensors > > frequency range via iio sysfs") > > > > I think your email broke this line, it should be a single line. Other than that ... > > > Signed-off-by: Gwendal Grignou <gwendal@xxxxxxxxxxxx> > > Reviewed-by: Enric Balletbo i Serra <enric.balletbo@xxxxxxxxxxxxx> Applied to the fixes-togreg branch of iio.git and marked for stable. Thanks, Jonathan > > > --- > > Change since v1: Fix spelling. > > > > drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c | 5 ++++- > > 1 file changed, 4 insertions(+), 1 deletion(-) > > > > diff --git a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c > > index 156848d27c473..213837c2ecee2 100644 > > --- a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c > > +++ b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c > > @@ -85,10 +85,13 @@ static void get_default_min_max_freq(enum motionsensor_type type, > > > > switch (type) { > > case MOTIONSENSE_TYPE_ACCEL: > > - case MOTIONSENSE_TYPE_GYRO: > > *min_freq = 12500; > > *max_freq = 100000; > > break; > > + case MOTIONSENSE_TYPE_GYRO: > > + *min_freq = 25000; > > + *max_freq = 100000; > > + break; > > case MOTIONSENSE_TYPE_MAG: > > *min_freq = 5000; > > *max_freq = 25000; > >