Re: [PATCH v2] iio: cros_ec: Set Gyroscope default frequency to 25Hz

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Gwendal,

Thank you for your patch.

On 28/7/20 22:48, Gwendal Grignou wrote:
> BMI160 Minimium gyroscope frequency in normal mode is 25Hz.
> When older EC firmware do not report their sensors frequencies,
> use 25Hz as the minimum for gyroscope to be sure it works on BMI160.
> 
> Fixes: ae7b02ad2f32d ("iio: common: cros_ec_sensors: Expose cros_ec_sensors
> frequency range via iio sysfs")
> 

I think your email broke this line, it should be a single line. Other than that ...

> Signed-off-by: Gwendal Grignou <gwendal@xxxxxxxxxxxx>

Reviewed-by: Enric Balletbo i Serra <enric.balletbo@xxxxxxxxxxxxx>

> ---
> Change since v1: Fix spelling.
> 
>  drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c | 5 ++++-
>  1 file changed, 4 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c
> index 156848d27c473..213837c2ecee2 100644
> --- a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c
> +++ b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c
> @@ -85,10 +85,13 @@ static void get_default_min_max_freq(enum motionsensor_type type,
>  
>  	switch (type) {
>  	case MOTIONSENSE_TYPE_ACCEL:
> -	case MOTIONSENSE_TYPE_GYRO:
>  		*min_freq = 12500;
>  		*max_freq = 100000;
>  		break;
> +	case MOTIONSENSE_TYPE_GYRO:
> +		*min_freq = 25000;
> +		*max_freq = 100000;
> +		break;
>  	case MOTIONSENSE_TYPE_MAG:
>  		*min_freq = 5000;
>  		*max_freq = 25000;
> 



[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]