Viestissä Lauantai 21. Kesäkuuta 2003 01:45, Michael J. McGillick kirjoitti:
> Here you go:
> T:  Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#=  2 Spd=1.5 MxCh= 0
> D:  Ver= 1.10 Cls=00(>ifc ) Sub=00 Prot=00 MxPS= 8 #Cfgs=  1
> P:  Vendor=051d ProdID=0002 Rev= 0.06
> S:  Manufacturer=American Power Conversion
> S:  Product=Smart-UPS 1000 XL FW:631.3.D USB FW:1.5
> S:  SerialNumber=AS0315130454
> C:* #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr= 30mA
> I:  If#= 0 Alt= 0 #EPs= 1 Cls=03(HID  ) Sub=00 Prot=00 Driver=(none)
> E:  Ad=81(I) Atr=03(Int.) MxPS=   6 Ivl=100ms
>
> Looks like the last grouping shows the unit correctly. I take it this is a
> positive thing?

Yes, it is correctly detected as a HID class device but for some reason the 
hid driver isn't loaded. Try "modprobe hid" to load it manually and see if 
you can start NUT.

-- 
	Markku Kolkka
	markku.kolkka@xxxxxxxxxxxx