Re: [PATCH] hwmon: (coretemp) Document Atom E660 support

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, 28 Sep 2011 18:54:58 +0530, R, Durgadoss wrote:
> Yes. It's the same for all Medfield based Atom products.
> And it cannot be read from MSR_TEMPERATURE_TARGET.
> So, we have to add the model name in the driver.
> Currently I have added a OR inside the 'if' in adjust_tjmax Function.
> 
> if (c->x86_model == 0x1c || c->x86_model == 0x27) {
> 
> This fetches me 90 and I have confirmed it with the Hardware folks here.

Oh, BTW, there is magic in this block to adjust tjmax based on the
north bridge. Is there any such magic possible for Atom model 0x26?

-- 
Jean Delvare

_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors