Hi Jean, > -----Original Message----- > From: Jean Delvare [mailto:khali@xxxxxxxxxxxx] > Sent: Wednesday, September 28, 2011 7:20 PM > To: R, Durgadoss > Cc: LM Sensors; Yu, Fenghua; Alexander Stein > Subject: Re: [PATCH] hwmon: (coretemp) Document Atom E660 support > > On Wed, 28 Sep 2011 18:54:58 +0530, R, Durgadoss wrote: > > Yes. It's the same for all Medfield based Atom products. > > And it cannot be read from MSR_TEMPERATURE_TARGET. > > So, we have to add the model name in the driver. > > Currently I have added a OR inside the 'if' in adjust_tjmax Function. > > > > if (c->x86_model == 0x1c || c->x86_model == 0x27) { > > > > This fetches me 90 and I have confirmed it with the Hardware folks here. > > Oh, BTW, there is magic in this block to adjust tjmax based on the > north bridge. Is there any such magic possible for Atom model 0x26? I guess this is not needed now, since we know the tjmax is 90 for 0x26. Thanks, Durga _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors