On Mon, 13 Sep 2010 09:13:49 -0700, Guenter Roeck wrote: > It looks like data is passed between 8031 and host using LDA 11h and/or 12h > (power management). However, if those LDAs are active, it does not mean that > ADCs or fan control is active. The datasheet does not specify details of ADC > and fan control communication between host and 8031; that seems to be microcode > specific. Also, it looks like the 8031 code is system specific and not provided > by the chip vendor. So it might not even be possible to obtain ADC and fan control > status. > > Or, of course, I might simply be missing something. > > For sensors-detect, we could possibly tag ADC and fan control support to > LDA 11h and/or 12h. Would that make sense ? If there's hope to ever write a driver for this, yes it makes sense. If not, we're probably better off just claiming that the device has no monitoring features. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors