Hans de Goede wrote: > Jean Delvare wrote: > >> Rick, >> >> On Wed, 14 Feb 2007 14:43:09 -0500, Rick Wright wrote: >> >>> Thanks for the support Hans de Goede responded to me off list >>> suggesting that, in fact, I probably have a abituguru ver3 chip, not >>> a w83627ehf chip afterall. The problem is that this ver3 abituguru >>> chip is not fully supported by sensors, libsensors, etc. However, >>> he did point me to a userspace utility he wrote that I was able to >>> use to successfully interrogate my uGuru chip. All along I knew >>> this board probably used a uGuru setup. I will forward those >>> messages back to the list under this thread for others' benefit. >>> >>> On the other hand, the problem that lm_sensors still has is that it >>> was the sensors-detect script that originally reported that I had a >>> w83627ehf chip and ultimately led me down this path. Hans suggested >>> this is not a correct identification job and that sensors-detect >>> should be fixed. >> >> >> Hans is probably wrong. The Super-I/O chip detection is very reliable >> and I would ve very surprised if you do not have a Winbond W83627EHF. >> As a matter of fact, this hi-res picture of your motherboard: >> http://www.techpowerup.com/reviews/Abit/AT8/images/board_fullsize.jpg >> clearly shows a W83627EHF in the top-left-hand corner. >> >> But indeed there's also a uGuru chip on the board. Bad luck. >> > > Ah, so this board has 2 sensors chips. Rick, can you see if the > W83627EHF voltage are any good (IOW match the ones given by openguru)? > Due to labeling differences, I'm not 100% sure how to match up the output values for comparison. That said, both sensors & oguru give "reasonable" values. The oguru information is much more complete. With sensors: w83627ehf only gives voltage readings; (no valid fan speeds, no valid temps), but k8temp seems to give correct temp readings. Attached is the output from both sensors & oguru run ~2 seconds apart. I'm happy to continue to help testing, etc. I'd really like to get this board supported as I've deployed 3 into production environments and would like to implement automated health monitoring. Let me know how I can help. Rick -------------- next part -------------- An embedded and charset-unspecified text was scrubbed... Name: sensors.txt Url: http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20070215/1d02bb2b/attachment.txt -------------- next part -------------- An embedded and charset-unspecified text was scrubbed... Name: oguru.txt Url: http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20070215/1d02bb2b/attachment-0001.txt