Jean Delvare wrote: > I propose to divide the changes in three distinct steps: > > 1* Change the base scheme (temp_min1 -> temp1_min). This is the more > important change. > > 2* Change the hysteresis names (temp1_hyst -> temp1_max_hyst). Only some > drivers are impacted. Changes required to the library as well. > > 3* Add the splitted alarm files. This doesn't break the interface, but > on the other hand needs that we think about it a bit more so that out > choices are extendable and correct for all known drivers. Some temperature sensors have two types of alarms. An over-limit (max_alarm) alarm and a sensors failed alarm. We could do this a couple of different ways: 1. Name the alarm file for a sensor: temp1_alarm and have it take one of several values: "" (null string), "ALARM", "FAIL" 2. Come up with another name for the other alarm: temp1_input_failed? temp1_fail_alarm? 3. Some other idea I haven't thought of? FYI, :v) -- Philip Pokorny, Director of Engineering Tel: 415-358-2635 Fax: 415-358-2646 Toll Free: 888-PENGUIN PENGUIN COMPUTING, INC. www.penguincomputing.com