Re: [PATCH 1/2] watchdog: da9063: Ping watchdog only during allowed time window

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Guenter,

Am Freitag, den 07.08.2015, 06:36 -0700 schrieb Guenter Roeck:
> On 08/06/2015 09:36 AM, Philipp Zabel wrote:
> > There is a cooldown period after watchdog timer setup, and also after each
> > watchdog ping. If a ping is issued too early, the watchdog triggers the
> > watchdog error condition and causes a system reset.
> >
> > The 256 ms period length is a best guess based on the same value being used
> > for the DA9053 predecessor PMIC and experiments that have shown 200 ms are
> > not enough to avoid the error.
> >
> > Signed-off-by: Philipp Zabel <p.zabel@xxxxxxxxxxxxxx>
> 
> Hi Philipp,
> 
> instead of using this quite complex approach, would it be possible to use the
> same approach as the da9062 driver ?
> 
> I understand the downside, which is that the caller may end up sleeping,
> but this should not happen too often.

Depending on the userspace this can happen quite a lot ...

>  Also, I plan to move the enforcement
> of a minimal time between heartbeats into the infrastructure, so this would
> not least forever.

... but certainly taking care of this in the framework is better than
doing it in the drivers.

regards
Philipp

--
To unsubscribe from this list: send the line "unsubscribe linux-watchdog" in
the body of a message to majordomo@xxxxxxxxxxxxxxx