On Mon, 3 Feb 2025 20:39:20 +0100 Antoni Pokusinski <apokusinski01@xxxxxxxxx> wrote: > On Mon, Feb 03, 2025 at 11:26:27AM +0200, Andy Shevchenko wrote: > > On Sun, Feb 02, 2025 at 11:07:10AM +0100, Antoni Pokusinski wrote: > > > Applying the current scale value to the raw magnetic field measurements > > > gives the result in mT. > > > > > > Fix the scale by increasing it 10 times, so that the final result after > > > applying the scale is in Gauss. > > > > No objections against this change, just wondering since these are > > the ABI changes (correct?) how should we really handle them in case > > some of the user space stuff already relies on 'bad' values? > > > > -- > > With Best Regards, > > Andy Shevchenko > > > > > > Just to clarify: yes, this patch makes the output values compliant to > ABI (Documentation/ABI/testing/sysfs-bus-iio). According to the ABI, the > output values for the magnetic field should be in Gauss, but during > the driver development I missed the fact that I return values in mT > instead... (1 Gauss = 0.1mT) > > BTW I see that the patch cb29542a178f ("iio: magnetometer: si7210: add > driver for Si7210") is still on the "testing" branch only, so perhaps > it's still not too late to apply the fix? > Ah. I'd not registered that. Definitely makes life easier. This will just get queued up behind it and land upstream at the same time. Jonathan > Kind regards, > Antoni > >