On Mon, Feb 03, 2025 at 11:26:27AM +0200, Andy Shevchenko wrote: > On Sun, Feb 02, 2025 at 11:07:10AM +0100, Antoni Pokusinski wrote: > > Applying the current scale value to the raw magnetic field measurements > > gives the result in mT. > > > > Fix the scale by increasing it 10 times, so that the final result after > > applying the scale is in Gauss. > > No objections against this change, just wondering since these are > the ABI changes (correct?) how should we really handle them in case > some of the user space stuff already relies on 'bad' values? > > -- > With Best Regards, > Andy Shevchenko > > Just to clarify: yes, this patch makes the output values compliant to ABI (Documentation/ABI/testing/sysfs-bus-iio). According to the ABI, the output values for the magnetic field should be in Gauss, but during the driver development I missed the fact that I return values in mT instead... (1 Gauss = 0.1mT) BTW I see that the patch cb29542a178f ("iio: magnetometer: si7210: add driver for Si7210") is still on the "testing" branch only, so perhaps it's still not too late to apply the fix? Kind regards, Antoni