Fix reading unsigned data from the AD4000 ADC via the _raw sysfs attribute by ensuring that *val is set before returning from ad4000_single_conversion(). This was not being set in any code path and was causing the attribute to return a random value. Fixes: 938fd562b974 ("iio: adc: Add support for AD4000") Signed-off-by: David Lechner <dlechner@xxxxxxxxxxxx> --- FYI, there is also another unrelated bug I noticed but didn't fix. We are calling iio_push_to_buffers_with_timestamp() but there isn't actually a IIO_CHAN_SOFT_TIMESTAMP() channel. I assume the intention was to have the timestamp channel? --- drivers/iio/adc/ad4000.c | 2 ++ 1 file changed, 2 insertions(+) diff --git a/drivers/iio/adc/ad4000.c b/drivers/iio/adc/ad4000.c index 6ea491245084..fc9c9807f89d 100644 --- a/drivers/iio/adc/ad4000.c +++ b/drivers/iio/adc/ad4000.c @@ -344,6 +344,8 @@ static int ad4000_single_conversion(struct iio_dev *indio_dev, if (chan->scan_type.sign == 's') *val = sign_extend32(sample, chan->scan_type.realbits - 1); + else + *val = sample; return IIO_VAL_INT; } --- base-commit: fa4076314480bcb2bb32051027735b1cde07eea2 change-id: 20241030-iio-adc-ad4000-fix-reading-unsigned-data-88a1de88cf57 Best regards, -- David Lechner <dlechner@xxxxxxxxxxxx>