On Wed, 30 Oct 2024 16:09:41 -0500 David Lechner <dlechner@xxxxxxxxxxxx> wrote: > Fix reading unsigned data from the AD4000 ADC via the _raw sysfs > attribute by ensuring that *val is set before returning from > ad4000_single_conversion(). This was not being set in any code path > and was causing the attribute to return a random value. > > Fixes: 938fd562b974 ("iio: adc: Add support for AD4000") > Signed-off-by: David Lechner <dlechner@xxxxxxxxxxxx> Applied. > --- > FYI, there is also another unrelated bug I noticed but didn't fix. > > We are calling iio_push_to_buffers_with_timestamp() but there isn't > actually a IIO_CHAN_SOFT_TIMESTAMP() channel. I assume the intention > was to have the timestamp channel? Technically harmless as it can never be turned on, but indeed seems doubtful - maybe something to treat as a feature rather than a fix though given it was never there. > --- > drivers/iio/adc/ad4000.c | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/drivers/iio/adc/ad4000.c b/drivers/iio/adc/ad4000.c > index 6ea491245084..fc9c9807f89d 100644 > --- a/drivers/iio/adc/ad4000.c > +++ b/drivers/iio/adc/ad4000.c > @@ -344,6 +344,8 @@ static int ad4000_single_conversion(struct iio_dev *indio_dev, > > if (chan->scan_type.sign == 's') > *val = sign_extend32(sample, chan->scan_type.realbits - 1); > + else > + *val = sample; > > return IIO_VAL_INT; > } > > --- > base-commit: fa4076314480bcb2bb32051027735b1cde07eea2 > change-id: 20241030-iio-adc-ad4000-fix-reading-unsigned-data-88a1de88cf57 > > Best regards,