On Sun, 17 Jan 2021 15:12:40 -0800 Matt Ranostay <matt.ranostay@xxxxxxxxxxxx> wrote: > On Sun, Jan 17, 2021 at 7:40 AM Jonathan Cameron <jic23@xxxxxxxxxx> wrote: > > > > From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> > > > > These contain only one entry for out_current_heater_raw (_available). > > Document this in a new sysfs-bus-iio-humidity file, and make it a little > > more generic by allowing for non 0/1 values. > > > > Fixes: > > $ scripts/get_abi.pl validate > > Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw is defined 2 times: ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:0 ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:0 > > Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available is defined 2 times: ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:1 ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:1 > > > > Cc: Eugene Zaikonnikov <ez@xxxxxxxxxxxxx> > > Cc: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx> > > Reported-by: Mauro Carvalho Chehab <mchehab+huawei@xxxxxxxxxx> > > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> > > Reviewed-by: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx> Applied, thanks J > > > --- > > ...s-bus-iio-humidity-hdc2010 => sysfs-bus-iio-humidity} | 3 ++- > > Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 --------- > > 2 files changed, 2 insertions(+), 10 deletions(-) > > > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 b/Documentation/ABI/testing/sysfs-bus-iio-humidity > > similarity index 79% > > rename from Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 > > rename to Documentation/ABI/testing/sysfs-bus-iio-humidity > > index 5b78af5f341d..cb0d7e75d297 100644 > > --- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 > > +++ b/Documentation/ABI/testing/sysfs-bus-iio-humidity > > @@ -6,4 +6,5 @@ Description: > > Controls the heater device within the humidity sensor to get > > rid of excess condensation. > > > > - Valid control values are 0 = OFF, and 1 = ON. > > + In some devices, this is just a switch in which case 0 = OFF, > > + and 1 = ON. > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x > > deleted file mode 100644 > > index b72bb62552cf..000000000000 > > --- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x > > +++ /dev/null > > @@ -1,9 +0,0 @@ > > -What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw > > -What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available > > -KernelVersion: 4.3 > > -Contact: linux-iio@xxxxxxxxxxxxxxx > > -Description: > > - Controls the heater device within the humidity sensor to get > > - rid of excess condensation. > > - > > - Valid control values are 0 = OFF, and 1 = ON. > > -- > > 2.30.0 > >