Re: [RFC PATCH 5/7] iio:ABI docs: Combine sysfs-bus-iio-humidity-hdc2010/hdc100x into one file

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Sun, Jan 17, 2021 at 7:40 AM Jonathan Cameron <jic23@xxxxxxxxxx> wrote:
>
> From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
>
> These contain only one entry for out_current_heater_raw (_available).
> Document this in a new sysfs-bus-iio-humidity file, and make it a little
> more generic by allowing for non 0/1 values.
>
> Fixes:
> $ scripts/get_abi.pl validate
> Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:0  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:0
> Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:1  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:1
>
> Cc: Eugene Zaikonnikov <ez@xxxxxxxxxxxxx>
> Cc: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>
> Reported-by: Mauro Carvalho Chehab <mchehab+huawei@xxxxxxxxxx>
> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>

Reviewed-by: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>

> ---
>  ...s-bus-iio-humidity-hdc2010 => sysfs-bus-iio-humidity} | 3 ++-
>  Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 ---------
>  2 files changed, 2 insertions(+), 10 deletions(-)
>
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 b/Documentation/ABI/testing/sysfs-bus-iio-humidity
> similarity index 79%
> rename from Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
> rename to Documentation/ABI/testing/sysfs-bus-iio-humidity
> index 5b78af5f341d..cb0d7e75d297 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
> +++ b/Documentation/ABI/testing/sysfs-bus-iio-humidity
> @@ -6,4 +6,5 @@ Description:
>                 Controls the heater device within the humidity sensor to get
>                 rid of excess condensation.
>
> -               Valid control values are 0 = OFF, and 1 = ON.
> +               In some devices, this is just a switch in which case 0 = OFF,
> +               and 1 = ON.
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
> deleted file mode 100644
> index b72bb62552cf..000000000000
> --- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
> +++ /dev/null
> @@ -1,9 +0,0 @@
> -What:          /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw
> -What:          /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available
> -KernelVersion: 4.3
> -Contact:       linux-iio@xxxxxxxxxxxxxxx
> -Description:
> -               Controls the heater device within the humidity sensor to get
> -               rid of excess condensation.
> -
> -               Valid control values are 0 = OFF, and 1 = ON.
> --
> 2.30.0
>