From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> The nature of IIO devices is that they are highly varied and occaisonly ABI is used in somewhat of a 'best fit' fashion. This has lead to a situation where we had additional more specific ABI docs for some sysfs parameters in certain drivers. Unfortunately the automated documentation building doesn't work well with this both issuing warnings and building a less than ideal output. So this series attempts to fix that up, mostly by moving the application specific parts, of properties that are documented in more than one place, into a higher level documentation file, sometimes with a device specific note. In a few cases this the result is a bit non-obvious hence the RFC. Roughly speaking I've put the more 'interesting' cases towards the end of the series. It's worth noting that a general reorganzation, audit of missing docs etc is needed for the IIO ABI docs, but as that's a big job it may well take sometime to get it done. In the meantime let's deal with these issues. Some of the drivers have complex enough ABI that we should probably have detailed docs for them in addition to Documentation/ABI. Note I haven't yet touched the remaining case of Warning: /sys/bus/iio/devices/iio:deviceX/in_count0_preset is defined 2 times: ./Documentation/ABI/testing/sysfs-bus-iio-timer-stm32:100 ./Documentation/ABI/testing/sysfs-bus-iio-lptimer-stm32:0 Warning: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available is defined 2 times: ./Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8:2 ./Documentation/ABI/testing/sysfs-bus-iio-lptimer-stm32:8 This is mainly because I don't really know enough about these devices to conclude exactly what a fused bit of docs should look like. Also worth noting that those are probably deprecated ABI anyway given the move of counters into their own subsystem. Jonathan Cameron (7): iio:ABI docs: Fix up duplicate *_calibbias_* documentation for icm42600 iio:ABI docs: Avoid repitition of triggerX/sampling_frequency iio:ABI docs: Drop device specific docs for _powerdown for the adf4371 iio:ABI docs: Fix issue around repeated definition of out_currentY_raw iio:ABI docs: Combine sysfs-bus-iio-humidity-hdc2010/hdc100x into one file iio:ABI docs: Combine the two instances of docs for sensor_sensitivity iio:ABI docs: Move specific description of out_altvoltageX_frequency to main docs. Documentation/ABI/testing/sysfs-bus-iio | 45 +++++++++++++++++++ .../ABI/testing/sysfs-bus-iio-distance-srf08 | 8 ---- .../testing/sysfs-bus-iio-frequency-adf4371 | 33 -------------- .../ABI/testing/sysfs-bus-iio-health-afe440x | 10 +---- ...umidity-hdc2010 => sysfs-bus-iio-humidity} | 3 +- .../testing/sysfs-bus-iio-humidity-hdc100x | 9 ---- .../ABI/testing/sysfs-bus-iio-icm42600 | 20 --------- .../testing/sysfs-bus-iio-light-lm3533-als | 11 ++--- .../ABI/testing/sysfs-bus-iio-proximity | 14 ++++++ .../testing/sysfs-bus-iio-proximity-as3935 | 9 ---- .../ABI/testing/sysfs-bus-iio-timer-stm32 | 8 ---- 11 files changed, 66 insertions(+), 104 deletions(-) rename Documentation/ABI/testing/{sysfs-bus-iio-humidity-hdc2010 => sysfs-bus-iio-humidity} (79%) delete mode 100644 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x delete mode 100644 Documentation/ABI/testing/sysfs-bus-iio-icm42600 -- 2.30.0