Am 04.01.22 um 13:37 schrieb Oliver Hartkopp: >> actually spec says *average* gap time should not fall below STMIN. > > I did not see this average gap recommendation so far. > > Only: > > 9.6.5.4 > SeparationTime minimum (STmin) parameter definition > > The ST min parameter shall be encoded in byte #3 of the FC N_PCI. > > This time is specified by the receiving entity. The STmin parameter > value specifies the minimum time > gap allowed between the transmissions of two ConsecutiveFrame network > protocol data units (CFs). Hi, the *average* info is from a german translation. There is a note at the end of the section where it states that due to jitter in networking, *average* st's comply to STmin. I confirm that this note is not in the English ISO15765-2-2016. Regards, Patrick