try this :
  • SetupTimeout=4000
    Default: 8000
  • A timeout value (in milliseconds) to wait for a first message (Setup) to be received after a signaling TCP channel has been opended.
  • SignalTimeout=10000
    Default: 15000
  • A timeout value (in milliseconds) to wait for a signalling channel to be opened after an ACF message is sent or to wait for an Alerting message after a signalling channel has been opened. This option can be thought as a maximum allowed PDD (Post Dial Delay) value.
  • AlertingTimeout=60000
    Default: 180000
  • A timeout value (in milliseconds) to wait for a Connect message after a call entered Alerting state. This option can be thought as a maximum "ringing time".