try this :- SetupTimeout=4000
Default: 8000 - A timeout value (in milliseconds) to wait for a first message (Setup) to be received after a signaling TCP channel has been opended.
- SignalTimeout=10000
Default: 15000 - A timeout value (in milliseconds) to wait for a signalling channel to be opened after an ACF message is sent or to wait for an Alerting message after a signalling channel has been opened. This option can be thought as a maximum allowed PDD (Post Dial Delay) value.
- AlertingTimeout=60000