Re: Why set osd flag to noout during upgrade ?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Indeed.  In a large enough cluster, even a few minutes of extra backfill/recovery per OSD adds up.  Say you have 100 OSD nodes, and just 3 minutes of unnecessary backfill per.  That prolongs your upgrade by 5 hours.



> Yeah you don't want to deal with backfilling while the cluster is
> upgrading. At best it can delay the upgrade, at worst mixed version
> backfilling has (rarely) caused issues in the past.
> 
> We additionally `set noin` and disable the balancer: `ceph balancer off`.
> The former prevents broken osds from re-entering the cluster, and both of
> these similarly prevent backfilling from starting mid-upgrade.
> 
> 
> .. Dan
> 
> 
> On Wed, 22 Sep 2021, 12:18 Etienne Menguy, <etienne.menguy@xxxxxxxx> wrote:
> 
>> Hello,
>> 
>> From my experience, I see three reasons :
>> - You don’t want to recover data if you already have them on a down OSD,
>> rebalancing can have a big impact on performance
>> - If upgrade/maintenance goes wrong you will want to focus on this issue
>> and not have to deal with things done by Ceph meanwhile.
>> - During an upgrade you have an ‘unusual’ cluster with different versions.
>> It’s supposed to work, but you probably want to keep it ‘boring’.
>> 
>> -
>> Etienne Menguy
>> etienne.menguy@xxxxxxxx
>> 
>> 
>> 
>> 
>>> On 22 Sep 2021, at 11:51, Francois Legrand <fleg@xxxxxxxxxxxxxx> wrote:
>>> 
>>> Hello everybody,
>>> 
>>> I have a "stupid" question. Why is it recommended in the docs to set the
>> osd flag to noout during an upgrade/maintainance (and especially during an
>> osd upgrade/maintainance) ?
>>> 
>>> In my understanding, if an osd goes down, after a while (600s by
>> default) it's marked out and the cluster will start to rebuild it's content
>> elsewhere in the cluster to maintain the redondancy of the datas. This
>> generate some transfer and load on other osds, but that's not a big deal !
>>> 
>>> As soon as the osd is back, it's marked in again and ceph is able to
>> determine which data is back and stop the recovery to reuse the unchanged
>> datas which are back. Generally, the recovery is as fast as with noout flag
>> (because with noout, the data modified during the down period still have be
>> copied to the back osd).
>>> 
>>> Thus is there an other reason apart from limiting the transfer and
>> others osds load durind the downtime ?
>>> 
>>> F
>>> 
>>> _______________________________________________
>>> ceph-users mailing list -- ceph-users@xxxxxxx
>>> To unsubscribe send an email to ceph-users-leave@xxxxxxx
>> 
>> _______________________________________________
>> ceph-users mailing list -- ceph-users@xxxxxxx
>> To unsubscribe send an email to ceph-users-leave@xxxxxxx
>> 
> _______________________________________________
> ceph-users mailing list -- ceph-users@xxxxxxx
> To unsubscribe send an email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx




[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]