Re: [External Email] Re: Ceph Nautius not working after setting MTU 9000

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Amudhan,

Here is a trick I've used to test and evaluate Jumbo Frames without breaking production traffic:

 * Open a couple root ssh sessions on each of the two systems you want
   to test with.
     o   In one window start a continuous ping to the other system.
 * On both test systems:
     o Look at the output of 'ip route list'.
     o Use 'ip route change' to explicitly set the MTU of all of your
       routes to 1500.
     o Review the output of 'ip route list' to assure you got them all.
     o Use 'ip link set' to set the MTU of the interface.
         + Size of all packets is still 1500 due to the route MTUs
         + Ping should still be working like normal.
 * Using 'ip addr add' to create a test logical IP on each of the two
   systems - use something unrelated to your production IP addresses,
   like 2.2.2.2/24 and 2.2.2.3/24.
     o Go back to the procedure above and find any new routes
       associated with the addresses you just added.
         + Use 'ip addr change' to set the MTU of these new routes to
           8192.
     o Default route not needed.
 * Using the test interfaces try 'ping -s 5000'  or anything above 1500.
     o If this works, you have everything, including your network
       switches, set up correctly, and you're sending packets larger
       that 1500.
     o Yet your SSH sessions and all production traffic are still
       running at MTU 1500.
     o Since the route MTUs for these spare logical IPs is 8192, you
       should be able probe up to 'ping -s 8150' or higher, but I think
       you need to leave space for the IP and ICMP headers.

The nice thing about this is that you haven't disrupted your production traffic at this point, and in the worst case you can undo all of these changes by rebooting the two test nodes.

If you want to move your production traffic to Jumbo Frames, change the appropriate routes to MTU 8192 on all systems.  Then test test test.  Lastly, change your network configuration on any effected nodes so the increased MTU will be reinstated after every reboot.

-Dave

Dave Hall
Binghamton University

On 5/24/2020 9:53 AM, Suresh Rama wrote:
Ping with 9000 MTU won't get response as I said and it should be 8972. Glad
it is working but you should know what happened to avoid this issue later.

On Sun, May 24, 2020, 3:04 AM Amudhan P <amudhan83@xxxxxxxxx> wrote:

No, ping with MTU size 9000 didn't work.

On Sun, May 24, 2020 at 12:26 PM Khodayar Doustar <doustar@xxxxxxxxxxxx>
wrote:

Does your ping work or not?


On Sun, May 24, 2020 at 6:53 AM Amudhan P <amudhan83@xxxxxxxxx> wrote:

Yes, I have set setting on the switch side also.

On Sat 23 May, 2020, 6:47 PM Khodayar Doustar, <doustar@xxxxxxxxxxxx>
wrote:

Problem should be with network. When you change MTU it should be
changed
all over the network, any single hup on your network should speak and
accept 9000 MTU packets. you can check it on your hosts with "ifconfig"
command and there is also equivalent commands for other
network/security
devices.

If you have just one node which it not correctly configured for MTU
9000
it wouldn't work.

On Sat, May 23, 2020 at 2:30 PM sinan@xxxxxxxx <sinan@xxxxxxxx> wrote:

Can the servers/nodes ping eachother using large packet sizes? I guess
not.

Sinan Polat

Op 23 mei 2020 om 14:21 heeft Amudhan P <amudhan83@xxxxxxxxx> het
volgende geschreven:
In OSD logs "heartbeat_check: no reply from OSD"

On Sat, May 23, 2020 at 5:44 PM Amudhan P <amudhan83@xxxxxxxxx>
wrote:
Hi,

I have set Network switch with MTU size 9000 and also in my netplan
configuration.

What else needs to be checked?


On Sat, May 23, 2020 at 3:39 PM Wido den Hollander <wido@xxxxxxxx
wrote:


On 5/23/20 12:02 PM, Amudhan P wrote:
Hi,

I am using ceph Nautilus in Ubuntu 18.04 working fine wit MTU
size
1500
(default) recently i tried to update MTU size to 9000.
After setting Jumbo frame running ceph -s is timing out.
Ceph can run just fine with an MTU of 9000. But there is probably
something else wrong on the network which is causing this.

Check the Jumbo Frames settings on all the switches as well to
make
sure
they forward all the packets.

This is definitely not a Ceph issue.

Wido

regards
Amudhan P
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx




[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]