Hello David,
Thank you and I'm terribly sorry; I was unaware I was starting new threads.
From the top of my mind I say "yes it'll fit" but obviously I make sure
at first.
Regards,
Kees
On 21-08-18 16:34, David Turner wrote:
Ceph does not support downgrading OSDs. When you removed the single
OSD, it was probably trying to move data onto the other OSDs in the
node with Infernalis OSDs. I would recommend stopping every OSD in
that node and marking them out so the cluster will rebalance without
them. Assuming your cluster is able to get healthy after that, we'll
see where things are.
Also, please stop opening so many email threads about this same
issue. It makes tracking this in the archives impossible.
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com