Richard Lithvall wrote: > Klaus Schmidinger wrote: > ... >>> OK, so if I send my "not known to be good" data with table id 0x50 >>> and higher (or even 0x6F just to be sure), it would be overwritten by >>> the providers EPG-data when they send their (conflicting) >>> present/following events (0x4E/0x4F)? >> >> >> Events from the data stream with table ids that are less than an >> existing event with the same event id or start time will overwrite >> the existing data. > > > Sounds promising for my needs. To make sure I understand I'll try to > summarize; > > If I populate a channel with custom EPG-data and setting <table id> to > 0x6F and the <event id> to some random made up unique value the EPG-data > will always be overwritten by events coming from the providers data > stream as long as the <table id> is less than 0x6F and start time are > the same no matter what the <event id> are? That's how it's supposed to be. Klaus