Hi Stefan, On 19-10-02 09:34, Stefan Riedmüller wrote: > Hi Marco, Sascha, > On 02.10.19 09:23, Sascha Hauer wrote: > > Marco, > > > > On Wed, Oct 02, 2019 at 09:20:43AM +0200, Sascha Hauer wrote: > > > +Cc Christian Hemp who is the author of b6bebb7aca > > > > > > On Wed, Sep 11, 2019 at 04:53:28PM +0200, Marco Felsch wrote: > > > > The PMIC is connected to i2c3 and not i2c1. > > > > > > > > Fixes: b6bebb7aca ("ARM: i.MX: phytec-som-imx6: phycore: Set BUCK mode to SYNC") > > > > Signed-off-by: Marco Felsch <m.felsch@xxxxxxxxxxxxxx> > > > > --- > > > > arch/arm/boards/phytec-som-imx6/board.c | 2 +- > > > > 1 file changed, 1 insertion(+), 1 deletion(-) > > > > > > > > diff --git a/arch/arm/boards/phytec-som-imx6/board.c b/arch/arm/boards/phytec-som-imx6/board.c > > > > index 730115702b..38e5ede91a 100644 > > > > --- a/arch/arm/boards/phytec-som-imx6/board.c > > > > +++ b/arch/arm/boards/phytec-som-imx6/board.c > > > > @@ -117,7 +117,7 @@ static int phycore_da9062_setup_buck_mode(void) > > > > struct i2c_adapter *adapter = NULL; > > > > struct i2c_client client; > > > > unsigned char value; > > > > - int bus = 0; > > > > + int bus = 2; > > > > int ret; > > > > adapter = i2c_get_adapter(bus); > > > > You could test it directly on b6bebb7aca instead of master. Is this > > change necessary there aswell or has the bus numbering changed in > > between? > > this bus numbering changed with Marco's patch to use the upstream device tree. > > ARM: dts: imx6: phycore: make use of upstream dts > > The phyCORE-i.MX 6 uses just one i2c interface but on the phyBOARD-Mira two > more i2c interfaces are used. Or if another baseboard uses the SoM and a Baseboard with more i2c interfaces. After talking with Sascha we should fix this by using of_find_i2c_adapter_by_node(). So it is fixed in my case and in your case too. Are you agree? Regards, Marco > > Stefan > > > > > Sascha > > > -- Pengutronix e.K. | | Industrial Linux Solutions | http://www.pengutronix.de/ | Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox