Hi Christian, thanks for the quick reply. > >Can you give any hints that makes it simpler to verify your fix or anything? > To reproduce the issue and test the fix I reseted the board in a loop. > For this I added 'reset' to /env/bin/init. With 'reset" in /env/bin/init I > saw the issue after 1 - 2 Minutes. > Also I have done 1000 power cuts and resets without any error in our > test rack. > > power cut: > 1. start barebox to prompt > 2. power cut > > soft reset: > 1. start barebox to prompt > 2. reset We have deployed an updated barebox in our test setup that do all our ON/OFF testing. A quick grep from the serial logs shows that we have seen this error message much more often than I originally anticipated. So I expect to have feedback already tomorrow. >From your information I am quite positive. Sam _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox