On Tue, 19 May 2015, Thomas Fjellstrom wrote:
How many UREs are considered "ok"? Tens, hundreds, thousands, tens of thousands?
I will replace any drive that have developed UNC sectors a few times, so I'd say "less than 10".
+1 on the "set kernel timeout to more than 120 seconds". I have this in /etc/rc.local:
for x in /sys/block/sd[a-z] ; do echo 180 > $x/device/timeout done echo 4096 > /sys/block/md0/md/stripe_cache_size -- Mikael Abrahamsson email: swmike@xxxxxxxxx -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html