Hi all,
I am testing lvmcache with VDO and I have issue with devices block size.
The big & slow VDO device is on top of a 4-disk MD RAID 10 device
(itself on top of dm-integrity). Over the VDO device I created a
thinpool and a thinvol [1]. When adding the cache device to the volume
group via vgextend, I get an error stating "Devices have inconsistent
logical block sizes (4096 and 512)." [2]
Now, I know why the error shows and what i means. However, I don't know
how to force the cache device to act as a 4k sector device, and/if this
is really required to cache a VDO device.
My current workaround is to set VDO with --emulate512=enabled, but this
can be suboptimal and it is not recommended.
Any idea on what I am doing wrong?
Thanks.
[1] Output from lsblk -t:
[root@singularity dev]# lsblk -t | cut -c1-73
NAME ALIGNMENT MIN-IO OPT-IO PHY-SEC
LOG-SEC
sda 0 512 0 512 512
├─sda1 0 512 0 512 512
├─sda2 0 512 0 512 512
│ ├─system-root 0 512 0 512 512
│ └─system-swap 0 512 0 512 512
├─sda3 0 512 0 512 512
└─sda4 0 512 0 512 512
sdb 0 512 0 512 512
└─sdb 0 512 0 512 512
└─md200 0 524288 1048576 512 512
└─vdo1 0 4096 4096 4096 4096
├─vg_kvm-thinpool_tmeta 0 4096 4096 4096 4096
│ └─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
│ ├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
│ └─vg_kvm-thinvol 0 1048576 1048576 4096 4096
└─vg_kvm-thinpool_tdata 0 4096 4096 4096 4096
└─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
└─vg_kvm-thinvol 0 1048576 1048576 4096 4096
sdc 0 512 0 512 512
└─sdc 0 512 0 512 512
└─md200 0 524288 1048576 512 512
└─vdo1 0 4096 4096 4096 4096
├─vg_kvm-thinpool_tmeta 0 4096 4096 4096 4096
│ └─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
│ ├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
│ └─vg_kvm-thinvol 0 1048576 1048576 4096 4096
└─vg_kvm-thinpool_tdata 0 4096 4096 4096 4096
└─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
└─vg_kvm-thinvol 0 1048576 1048576 4096 4096
sdd 0 512 0 512 512
└─sdd 0 512 0 512 512
└─md200 0 524288 1048576 512 512
└─vdo1 0 4096 4096 4096 4096
├─vg_kvm-thinpool_tmeta 0 4096 4096 4096 4096
│ └─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
│ ├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
│ └─vg_kvm-thinvol 0 1048576 1048576 4096 4096
└─vg_kvm-thinpool_tdata 0 4096 4096 4096 4096
└─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
└─vg_kvm-thinvol 0 1048576 1048576 4096 4096
sde 0 512 0 512 512
└─sde 0 512 0 512 512
└─md200 0 524288 1048576 512 512
└─vdo1 0 4096 4096 4096 4096
├─vg_kvm-thinpool_tmeta 0 4096 4096 4096 4096
│ └─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
│ ├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
│ └─vg_kvm-thinvol 0 1048576 1048576 4096 4096
└─vg_kvm-thinpool_tdata 0 4096 4096 4096 4096
└─vg_kvm-thinpool-tpool 0 1048576 1048576 4096 4096
├─vg_kvm-thinpool 0 1048576 1048576 4096 4096
└─vg_kvm-thinvol 0 1048576 1048576 4096 4096
[2] [root@singularity dev]# vgextend vg_kvm /dev/sda4
Devices have inconsistent logical block sizes (4096 and 512).
--
Danti Gionatan
Supporto Tecnico
Assyoma S.r.l. - www.assyoma.it
email: g.danti@xxxxxxxxxx - info@xxxxxxxxxx
GPG public key ID: FF5F32A8
_______________________________________________
linux-lvm mailing list
linux-lvm@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-lvm
read the LVM HOW-TO at http://tldp.org/HOWTO/LVM-HOWTO/