On Fri, Jan 22, 2016 at 5:02 PM, Stéphan Kochen <stephan@xxxxxxxxx> wrote: > On Fri, Jan 22, 2016 at 04:45:42PM -0600, Rob Herring wrote: >> On Thu, Jan 21, 2016 at 08:34:37PM +0100, Stéphan Kochen wrote: >> > +- #thermal-sensor-cells: Should be 1. See ../../thermal/thermal.txt for a >> > + description of this property. Use the following >> > + values to refer to a specific sensor: >> > + 0: chip internal sensor >> > + 1: external sensor >> > + 2: second external sensor, if present >> >> From my read of an LM90 datasheet, there is only an onchip sensor and a >> single external one. > > MAX6695 and MAX6696 have two external sensors, and also use the lm90 > driver. (The LM90_HAVE_TEMP3 flag in the code.) Okay. This change alone seems fine, but I agree with Guenter's comments. I think having the data in DT is fine, but it should be something common. Rob _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors