Re: [PATCH 3/3] lm90: register with thermal zones

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Fri, Jan 22, 2016 at 04:45:42PM -0600, Rob Herring wrote:
> On Thu, Jan 21, 2016 at 08:34:37PM +0100, Stéphan Kochen wrote:
> > +- #thermal-sensor-cells: Should be 1. See ../../thermal/thermal.txt for a
> > +                         description of this property. Use the following
> > +                         values to refer to a specific sensor:
> > +                         0: chip internal sensor
> > +                         1: external sensor
> > +                         2: second external sensor, if present
> 
> From my read of an LM90 datasheet, there is only an onchip sensor and a 
> single external one.

MAX6695 and MAX6696 have two external sensors, and also use the lm90
driver. (The LM90_HAVE_TEMP3 flag in the code.)

-- 
Stéphan Kochen

_______________________________________________