Hi Mike, On Mon, 18 Nov 2013 13:56:28 -0500, Mike Gilbert wrote: > > Do you have any additional information pertaining to ticket 2382? > > The CPU card we use in our products is going end-of-life. The CPU card > vendor send us a new card that is supposed to be a drop in replacement > (it's the same card with a newer Atom chip). The new card returns an > error when reading the coretemp: > > # cat /sys/bus/platform/devices/coretemp.0/temp2_input > cat: read error: Resource temporarily unavailable > # > > Some printk debugging yields: > > ENTER show_temp > status_reg @ 19C > eax = 8620000 edx = 0 > temp = 0 valid = 0 > EXIT show_temp > > This looks like the same issue described in your ticket 2382. Indeed. > Any information you can provide will be appreciated. Unfortunately, no, I do not have any additional information about this issue. I can only recommend using the external hardware monitoring chip (if there is one) instead of coretemp to monitor the temperature of these CPUs. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors