On Mon, 11 Nov 2013 18:37:37 -0800, Guenter Roeck wrote: > On 11/11/2013 04:57 PM, p. stephen w wrote: > > Please see attached. > > _____________________________________________________________________________________________ > > I noticed the fancontrol file is using hwmon2, instead of hwmon3, so I ran > > that command using hwmon2 and it has a lot more output. I've attached it > > in case its of interest. > > Can I set INTERVAL to less than a minute; 0.25, or 0.5? > > No idea. Interval is expressed in seconds, not minutes. The default is 10 seconds, which some may find too much if the low fan speeds are very low and temperatures can raise quickly. Lowering it is OK, but there's no point in going below 1 second because most hwmon drivers won't refresh their values faster than every second anyway. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors