Re: [PATCH v5 0/3] Add power control for lm90

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi, Jean
Since no more comments on this series, could you take this series before
the 3.13 merge window ?
Because if without this series, the lm90 will be broken on the Tegra
Dalmore board, and this problem will be get into the v3.13 release.

Looking forward to your reply :)

Thanks.
Wei.

On 10/18/2013 09:45 AM, Wei Ni wrote:
> On 10/16/2013 11:20 AM, Wei Ni wrote:
>> Hi, Jean
>>
>> Do you have any comments on this series, or will you take them ?
> 
> Hi, Jean, will you apply this series befor the 3.13 merge window?
> 
> Since I forgot to tell Stephen not to apply the "[PATCH 0/2] Update dts
> file to support lm90 well" untile this series are accept, so if without
> this change, the lm90 may be broken on the Dalmore board.
> 
> Thanks.
> Wei.
> 
>>
>> Thanks.
>> Wei.
>>
>> On 10/07/2013 05:25 PM, Wei Ni wrote:
>>> The device lm90 can be controlled by the vcc rail.
>>> Add function to power on/off the vcc.
>>> I will update all .dts files referencing this driver to
>>> match the new requirement in my next series.
>>>
>>> This series is v5, previous version patches are:
>>> [v4]: http://www.spinics.net/lists/lm-sensors/msg39583.html
>>> [v3]: http://www.spinics.net/lists/lm-sensors/msg39503.html
>>> [v2]: http://www.spinics.net/lists/arm-kernel/msg265373.html
>>> [v1]: http://www.mail-archive.com/linux-tegra@xxxxxxxxxxxxxxx/msg12034.html
>>>
>>> Changes from v4:
>>> 1. set vcc-supply as required property.
>>>
>>> Changes from v3:
>>> 1. change to use devm_regulator_get, as per discussion in previous patches.
>>> 2. just return errors when get error from regulator_get(), Mark's new dummy
>>> regulator can cope with errors.
>>> 3. add vendor prefix for GMT
>>> 3. list manufacturer in the binding doc.
>>>
>>> Changes from v2:
>>> 1. use devm_regulator_get_optional(), as suggested by Mark.
>>> 2. remove the lm90_power_control(), enable the regulator in the probe()
>>> directly, so the codes are more clear, as suggested by Alexander and Guenter.
>>> 3. change the binding documentation, as per Stephen suggestion.
>>> 4. couple of changes, as per previous review.
>>>
>>> Changes from v1:
>>> 1. if get regulator failed, we should continue to run probe function,
>>> not return fail.
>>> 2. call regulator_put() in error handler and remove function.
>>> 3. add LM90 DT binding document.
>>>
>>> Wei Ni (3):
>>>   hwmon: (lm90) Add power control
>>>   of: add vendor prefix for GMT
>>>   Documentation: dt: hwmon: add OF document for LM90
>>>
>>>  Documentation/devicetree/bindings/hwmon/lm90.txt   |   44 ++++++++++++++++++++
>>>  .../devicetree/bindings/vendor-prefixes.txt        |    1 +
>>>  drivers/hwmon/lm90.c                               |   19 +++++++++
>>>  3 files changed, 64 insertions(+)
>>>  create mode 100644 Documentation/devicetree/bindings/hwmon/lm90.txt
>>>
>>
> 