On Wed, Mar 27, 2013 at 12:14:36AM +0100, Hajdu Tamás Márk wrote: > Hi, > > I have a Gigabyte E240N mainboard (integrated amd cpu and gpu), > which by pwmconfig reported to use it87 module. This is for first > sight works, but one out of 3 temperature reading is always -70 > degrees (though it is the temp3, which I don't know what), other two Most likely it is not connected to anything. > seems to good. Also the fan speed readings seems to be ok (I am not > 100% sure). What it really does, that hwmon1 is created and there > are changing values so at least it is partially working. > I have tried to use pwmconfig to configure and also tried to echo > values I could think of, but I could not set (nor pwmconfig could) > it's speed. Fan control may be in automatic mode. That is the case if pwmX_enable returns 2. If so, you are most likely better off by leaving it alone. Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors