Make sure to clear the mode bits from the config register before setting the new mode. Otherwise we might end up with a different mode than we want to. Signed-off-by: Lars-Peter Clausen <lars@xxxxxxxxxx> --- drivers/hwmon/adt7410.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/hwmon/adt7410.c b/drivers/hwmon/adt7410.c index 797c2b8..4ccee4f 100644 --- a/drivers/hwmon/adt7410.c +++ b/drivers/hwmon/adt7410.c @@ -364,6 +364,7 @@ static int adt7410_probe(struct i2c_client *client, /* * Set to 16 bit resolution, continous conversion and comparator mode. */ + ret &= ~ADT7410_MODE_MASK; data->config = ret | ADT7410_FULL | ADT7410_RESOLUTION | ADT7410_EVENT_MODE; if (data->config != data->oldconfig) { -- 1.8.0 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors