[PATCH 1/9] hwmon: (adt7410) Clear unwanted bits in the config register

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Make sure to clear the mode bits from the config register before setting the new
mode. Otherwise we might end up with a different mode than we want to.

Signed-off-by: Lars-Peter Clausen <lars@xxxxxxxxxx>
---
 drivers/hwmon/adt7410.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/hwmon/adt7410.c b/drivers/hwmon/adt7410.c
index 797c2b8..4ccee4f 100644
--- a/drivers/hwmon/adt7410.c
+++ b/drivers/hwmon/adt7410.c
@@ -364,6 +364,7 @@ static int adt7410_probe(struct i2c_client *client,
 	/*
 	 * Set to 16 bit resolution, continous conversion and comparator mode.
 	 */
+	ret &= ~ADT7410_MODE_MASK;
 	data->config = ret | ADT7410_FULL | ADT7410_RESOLUTION |
 			ADT7410_EVENT_MODE;
 	if (data->config != data->oldconfig) {
-- 
1.8.0


_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors


[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]