On Thu, 18 Nov 2010 09:31:36 +0200, Thanasis wrote: > ~ # sensors > coretemp-isa-0000 > Adapter: ISA adapter > ERROR: Can't get value of subfeature temp1_input: Can't read > Core 0: +0.0°C (crit = +100.0°C) > > coretemp-isa-0001 > Adapter: ISA adapter > ERROR: Can't get value of subfeature temp1_input: Can't read > Core 1: +0.0°C (crit = +100.0°C) > (...) > ~ # > > Is the above ERROR normal? No, it is not. A more recent version of lm-sensors would display N/A as the temperature instead of the error message, but the problem remains. > Is there something I can/should do/configure about it? This is a hardware or driver issue, not sure yet. We had similar reports for other Atom CPUs, I don't know if this means these CPUs just don't have working sensors, or if there's any workaround the driver could apply to get them to work. Nothing you can do as a user anyway. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors