On 01/06/11 16:50, Guenter Roeck wrote: > On Thu, Jan 06, 2011 at 11:33:00AM -0500, Jean Delvare wrote: >> On Thu, 6 Jan 2011 08:00:42 -0800, Guenter Roeck wrote: >>> The humidity attribute is already supported by the sht15 driver, and another >>> driver supporting it is about to be added. Make it official. >>> >>> Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> >>> --- >>> Documentation/hwmon/sysfs-interface | 9 +++++++++ >>> 1 files changed, 9 insertions(+), 0 deletions(-) >>> >>> diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface >>> index 5997b5e..033fe76 100644 >>> --- a/Documentation/hwmon/sysfs-interface >>> +++ b/Documentation/hwmon/sysfs-interface >>> @@ -505,6 +505,15 @@ energy[1-*]_input Cumulative energy use >>> RO >>> >>> >>> +************ >>> +* Humidity * >>> +************ >>> + >>> +humidity[1-*]_input Humidity >>> + Unit: percent >> >> Are you sure? The sht15 driver source code suggests millipercent. >> Jonathan? Oops, not one of my better bits of reviewing... >> > Yes, you are right. Just noticed that as well. > > What would be the best term to use ? millipercent ? milli-percent ? per cent mille ? > The latter is the official term. How about > Unit: per cent mille (pcm, milli-percent) could multiply values by 10 then use Permyriad :) Otherwise maybe just write it out clearly as 'thousandth of a percent'? > > Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors