On Thu, Jan 06, 2011 at 11:33:00AM -0500, Jean Delvare wrote: > On Thu, 6 Jan 2011 08:00:42 -0800, Guenter Roeck wrote: > > The humidity attribute is already supported by the sht15 driver, and another > > driver supporting it is about to be added. Make it official. > > > > Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> > > --- > > Documentation/hwmon/sysfs-interface | 9 +++++++++ > > 1 files changed, 9 insertions(+), 0 deletions(-) > > > > diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface > > index 5997b5e..033fe76 100644 > > --- a/Documentation/hwmon/sysfs-interface > > +++ b/Documentation/hwmon/sysfs-interface > > @@ -505,6 +505,15 @@ energy[1-*]_input Cumulative energy use > > RO > > > > > > +************ > > +* Humidity * > > +************ > > + > > +humidity[1-*]_input Humidity > > + Unit: percent > > Are you sure? The sht15 driver source code suggests millipercent. > Jonathan? > Yes, you are right. Just noticed that as well. What would be the best term to use ? millipercent ? milli-percent ? per cent mille ? The latter is the official term. How about Unit: per cent mille (pcm, milli-percent) Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors