On Thu, 6 Jan 2011 08:50:03 -0800, Guenter Roeck wrote: > On Thu, Jan 06, 2011 at 11:33:00AM -0500, Jean Delvare wrote: > > On Thu, 6 Jan 2011 08:00:42 -0800, Guenter Roeck wrote: > > > The humidity attribute is already supported by the sht15 driver, and another > > > driver supporting it is about to be added. Make it official. > > > > > > Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> > > > --- > > > Documentation/hwmon/sysfs-interface | 9 +++++++++ > > > 1 files changed, 9 insertions(+), 0 deletions(-) > > > > > > diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface > > > index 5997b5e..033fe76 100644 > > > --- a/Documentation/hwmon/sysfs-interface > > > +++ b/Documentation/hwmon/sysfs-interface > > > @@ -505,6 +505,15 @@ energy[1-*]_input Cumulative energy use > > > RO > > > > > > > > > +************ > > > +* Humidity * > > > +************ > > > + > > > +humidity[1-*]_input Humidity > > > + Unit: percent > > > > Are you sure? The sht15 driver source code suggests millipercent. > > Jonathan? > > > Yes, you are right. Just noticed that as well. > > What would be the best term to use ? millipercent ? milli-percent ? per cent mille ? > The latter is the official term. How about > Unit: per cent mille (pcm, milli-percent) I'm fine either way. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors