On Wed, 15 Sep 2010 18:52:29 -0700, Guenter Roeck wrote: > Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> > --- > Documentation/hwmon/lm90 | 9 +++-- > Documentation/hwmon/sysfs-interface | 7 ++++ > drivers/hwmon/lm90.c | 65 +++++++++++++++++++++++++++++++--- > 3 files changed, 71 insertions(+), 10 deletions(-) > (...) > diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface > index 22843cb..4c73f3d 100644 > --- a/Documentation/hwmon/sysfs-interface > +++ b/Documentation/hwmon/sysfs-interface > @@ -317,6 +317,13 @@ temp[1-*]_emergency > Unit: millidegree Celsius > RW > > +temp[1-*]_emergency_hyst > + Temperature hysteresis value for emergency limit. > + Unit: millidegree Celsius > + Must be reported as an absolute temperature, NOT a delta > + from the emergency value. > + RW > + > temp[1-*]_lcrit Temperature critical min value, typically lower than > corresponding temp_min values. > Unit: millidegree Celsius I'll merge this chunk into hwmon-add-tempx_emergency-attribute-to-sysfs-abi.patch, I think it makes more sense that way. Other than that, no objection. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors