Thanks for the feedback, I'll adjust my implementation accordingly. Scott On Sep 4, 2010, at 9:42 AM, Jean Delvare wrote: > Hi Scott, > > On Mon, 30 Aug 2010 16:55:53 -0400, Scott Shanafelt wrote: >> chip "w83627dhg-*" >> >> label in0 "Vcore" >> label in1 "Vnbcore" > > This is "+1.05V" in SuperMicro's configuration file. > >> label in2 "AVCC" >> label in3 "3VCC" >> set in3_min 3.3 * 0.90 >> set in3_max 3.3 * 1.10 >> label in4 "VDIMM" >> label in5 "+5V" >> compute in5 @*4, @/4 >> label in6 "+12V" >> compute in6 @*16, @/16 >> set in6_min 12 * 0.90 >> set in6_max 12 * 1.10 >> label in7 "VSB" > > Better labelled as "3V3B". > >> label in8 "Vbat" >> >> label fan1 "fan1" >> ignore fan1 >> label fan2 "fan2" >> ignore fan2 >> label fan3 "fan3" >> ignore fan3 >> label fan4 "Case Fan" >> label fan5 "fan5" >> ignore fan5 > > Most of these labels are pointless, they are double no-ops (once > because they don't carry any meaning, twice because you end up ignoring > the input anyway.) What we want is fan locations, like: > > label fan2 "CPU Fan" > label fan4 "Case Fan" > > We also don't want to ignore a fan which exists on the board but you > happen to not use. "ignore fan2" shouldn't be there. > >> >> label temp1 "MB Temp" >> label temp2 "CPU Temp" >> label temp3 "Case Temp" >> >> ignore cpu0_vid > > I've added an updated configuration file here: > http://www.lm-sensors.org/wiki/Configurations/SuperMicro/X7SPA > > Thanks for your contribution. > > -- > Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors