On Thu, 26 Aug 2010, Guenter Roeck wrote: > Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> > --- > tempX_emergency will be used by max6696. It can also be used for other chips > supporting three upper temperature limits. > > Documentation/hwmon/sysfs-interface | 6 ++++++ > 1 files changed, 6 insertions(+), 0 deletions(-) > > diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface > index ff45d1f..1ceb2b9 100644 > --- a/Documentation/hwmon/sysfs-interface > +++ b/Documentation/hwmon/sysfs-interface > @@ -310,6 +310,12 @@ temp[1-*]_crit_hyst > from the critical value. > RW > > +temp[1-*]_emergency > + Temperature emergency value, typically greater than > + corresponding temp_crit values. > + Unit: millidegree Celsius > + RW > + If we have two-level alarms: critical, then emergency, it is best to have that written down than to imply it by "typically greater than corresponding temp_crit"... -- "One disk to rule them all, One disk to find them. One disk to bring them all and in the darkness grind them. In the Land of Redmond where the shadows lie." -- The Silicon Valley Tarot Henrique Holschuh _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors