Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> --- tempX_emergency will be used by max6696. It can also be used for other chips supporting three upper temperature limits. Documentation/hwmon/sysfs-interface | 6 ++++++ 1 files changed, 6 insertions(+), 0 deletions(-) diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index ff45d1f..1ceb2b9 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface @@ -310,6 +310,12 @@ temp[1-*]_crit_hyst from the critical value. RW +temp[1-*]_emergency + Temperature emergency value, typically greater than + corresponding temp_crit values. + Unit: millidegree Celsius + RW + temp[1-*]_lcrit Temperature critical min value, typically lower than corresponding temp_min values. Unit: millidegree Celsius -- 1.7.0.87.g0901d _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors