Jean Delvare wrote:
On Fri, 16 Jul 2010 13:21:55 -0700, Guenter Roeck wrote:
On Fri, Jul 16, 2010 at 03:55:28PM -0400, Patrick Nolan wrote:
Guenter Roeck wrote:
I guess upgrading may be the best approach. It looks like config file syntax
changed over time.
http://www.lm-sensors.org/wiki/Devices has this to say about k8temp:
Upgrade to lm_sensors 2.10.1 or later is mandatory, earlier versions of
libsensors will fail with a "General parse error" message.
If memory serves, it's unrelated to the configuration file. I'm almost
certain that you would get the error with "sensors -c /dev/null". The
"parsing" in question would be related to the device name (or more
exactly bus name - k8temp was our first PCI device supported as such.)
You were right. I upgraded to 2.10.7, and it works now.
# sensors
k8temp-pci-00c3
Adapter: PCI adapter
Core0 Temp:
+31°C
Core1 Temp:
+30°C
k8temp-pci-00cb
Adapter: PCI adapter
Core0 Temp:
+29°C
Core1 Temp:
+19°C
(That looks a bit odd. A 10 degree C difference?)
_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors