Op 10-11-09 13:41, Samu Onkalo schreef: > This patch set has earlier been sent to lm-sensors list (thus patch v2). > No changes after that except to patch 0006 to make it applicable to > 2.6.32-rc6 (no functional changes). : > > I have possibility to test these changes only with 8 bit version (lis302d). > Since part of the changes are specific to 12 bit device, I would appreciate > if someone could try these on 12 bit device. I've just tested them on a 12-bit device and it seems to go fine (excepted the rate setting in patch 8). Andrew, maybe you could already queue the first 5 patches, as they all look fine and are fixing bugs. So we are sure they are there for 2.6.33 :-) The rest of the patch series is useful but just "new feature" and some need more work. Thanks, Eric > > 0001: > Sync event is sent after each measurement. This helps user space > applications to detect which 3 reported values belongs to > one atomic measurement. > > 0002: > polled input device was not totally released in module unload. > This corrects memory leak. > > 0003: > This patch is originally from Eric Piel. > Updates documentation and chip ID handling > > 0004: > This patch is originally from Eric Piel. > Correction to sampling rate handling for 8 bit devices > > 0005: > Chip power on sequence was not waiting for chip to be ready. > This caused incorrect values right after the power on. _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors