Re: [PATCH v2 00/10] LIS3: Feature updates and corrections

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Op 10-11-09 13:41, Samu Onkalo schreef:
> This patch set has earlier been sent to lm-sensors list (thus patch v2).
> No changes after that except to patch 0006 to make it applicable to
> 2.6.32-rc6 (no functional changes).
:
> 
> I have possibility to test these changes only with 8 bit version (lis302d).
> Since part of the changes are specific to 12 bit device, I would appreciate
> if someone could try these on 12 bit device.
I've just tested them on a 12-bit device and it seems to go fine
(excepted the rate setting in patch 8).

Andrew, maybe you could already queue the first 5 patches, as they all
look fine and are fixing bugs. So we are sure they are there for 2.6.33
:-) The rest of the patch series is useful but just "new feature" and
some need more work.

Thanks,
Eric


> 
> 0001:
> Sync event is sent after each measurement. This helps user space
> applications to detect which 3 reported values belongs to
> one atomic measurement.
> 
> 0002:
> polled input device was not totally released in module unload.
> This corrects memory leak. 
> 
> 0003:
> This patch is originally from Eric Piel. 
> Updates documentation and chip ID handling
> 
> 0004:
> This patch is originally from Eric Piel.
> Correction to sampling rate handling for 8 bit devices
> 
> 0005:
> Chip power on sequence was not waiting for chip to be ready.
> This caused incorrect values right after the power on.

_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]