vt1211 patch

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

On Fri, May 26, 2006 at 11:37:14AM +0200, Juerg Haefliger wrote:
> Just realized that the temps are in millicelcius so the last line
> should read something like:
> echo 300000 > pwmX_auto_point4_temp
> The value written just needs to be large enough to saturate the
> register at 255 (it gets divided by 1000 in the driver before being
> written to the reg).

I tried your instructions, but nothing seems to happen:

| # cat pwm?_enable
| 2
| 2
| 
| # cat pwm?_auto_point4_temp
| 255000
| 255000

BTW that value seems the max I can set it to

sensors shows:

| CPU:      3105 RPM  (min =    0 RPM, div = 2)