lm78 on ep-61lxa-m not detected (#2042)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, 7 Sep 2005 09:01:20 +0200 (CEST), "Jean Delvare" <khali at linux-fr.org> wrote:
>
>OK, that's great, but I still would like the output of:
>isadump -y -f 0x290 8

Hi Jean,

# isadump -y -f 0x290 8
Error: Invalid range!
Hint: Must be a multiple of 16 no greater than 256.
Syntax for I2C-like access:
  isadump [-y] [-k V1,V2...] ADDRREG DATAREG [BANK [BANKREG]]
Syntax for flat address space:
  isadump [-y] -f ADDRESS [RANGE [BANK [BANKREG]]]


# isadump -y -f 0x290 16
     0  1  2  3  4  5  6  7  8  9  a  b  c  d  e  f
00: 01 ff ff 00 00 00 1a 80 ff ff ff ff 00 00 00 00

I also confirmed 2.9.2 sensors-detect has same behaviour as 2.9.1.

Cheers,
Grant.




[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]

  Powered by Linux