> I would suggest that the critical and hyst values belong in a > *seperate* proc entry. The /proc entries for temperature should > always and only be: > > high, low, current > or > over, hyst, current > > as appropriate to the sensor. Thanks for the suggestion, I just did that. As a side effect, it saved me from another problem (on the LM90, remote temp and remote tcrit have different magnitudes). > The whole /proc stuff is going away as Greg KH is so fond of > repeating and with sysfs, you've only got one value per entry so > this whole problem goes away. Still we have to live with it until the whole universe is using 2.6. BTW my driver is finished, I now need to update the library and sensors. -- Jean Delvare http://www.ensicaen.ismra.fr/~delvare/