Am Sonntag, 15. November 2009 00:57:49 schrieb Theodore Kilgore: > There is a sequence of commands used in the Windows driver for > setting up these cameras, which I omitted from the code in mr97310a.c. The > reason I omitted them is, some of them actually make the camera unstable > at some of the resolution settings. In particular, at 352x288 and at > 176x144. The OEM driver seems to assume that the camera will stream at > 320x240 and 160x120 only, even though it is capable of 352x288 and > 176x144. So, as I said, I omitted the whole sequence because it seemed to > be causing nothing but trouble. > > Well, so now I took a second look. There is exactly one command which sets > up the camera to stream properly if it is hooked up to a UHCI machine! I > assume, though I have no way of really knowing this without the usb > At what resolutions does it work now? Regards Oliver -- To unsubscribe from this list: send the line "unsubscribe linux-usb" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html