Re: [PATCH] xhci: Workaround to get Intel xHCI reset working more reliably

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 19.10.2015 17:37, Joe Lawrence wrote:
On 10/16/2015 03:29 AM, Rajmohan Mani wrote:
From: Rajmohan Mani <rajmohan.mani@xxxxxxxxx>

Existing Intel xHCI controllers require a delay of 1 mS,
after setting the CMD_RESET bit in command register, before
accessing any HC registers. This allows the HC to complete
the reset operation and be ready for HC register access.
Without this delay, the subsequent HC register access,
may result in a system hang, very rarely.

Verified CherryView / Braswell platforms go through over
5000 warm reboot cycles (which was not possible without
this patch), without any xHCI reset hang.

Signed-off-by: Rajmohan Mani <rajmohan.mani@xxxxxxxxx>

Hi Rajmohan,

Thanks for looking into this XHCI reset quirk.  We ran this patch on a
Stratus FT machine and it successfully reset ~1500 times over the weekend
without any issue.

Feel free to add:

Tested-by: Joe Lawrence <joe.lawrence@xxxxxxxxxxx>


Thanks for the patch.

Added the Tested-by tag and queued the patch

Will go forward to 4.4-rc1

-Mathias



--